Brookfield KU-1 Viscometer Manual de usuario

Busca en linea o descarga Manual de usuario para Instrumentos de medición Brookfield KU-1 Viscometer. Brookfield KU-1 Viscometer User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 13
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Brookfield Engineering Labs., Inc. Page 1 Manual No. M/97-241-B1101
BROOKFIELD KU-1+ VISCOMETER
Operating Instructions
Manual No. M/97-241-B1101
SPECIALISTS IN THE
MEASUREMENT AND
CONTROL OF VISCOSITY
T
EL
800-628-8139 or 508-946-6200 F
AX
508-946-6262
www.brookfieldengineering.com
BROOKFIELD ENGINEERING LABORATORIES, INC.
11 Commerce Boulevard, Middleboro, MA 02346-1031 USA
Vista de pagina 0
1 2 3 4 5 6 ... 12 13

Indice de contenidos

Pagina 1 - Manual No. M/97-241-B1101

Brookfield Engineering Labs., Inc. Page 1 Manual No. M/97-241-B1101BROOKFIELD KU-1+ VISCOMETEROperating InstructionsManual No. M/97-241-B1101SPECIALIS

Pagina 2 - TABLE OF CONTENTS

Brookfield Engineering Labs., Inc. Page 10 Manual No. M/97-241-B11015) Total allowable error for the calibration check in this example is 104.8 KU, ±

Pagina 3 - I. INTRODUCTION

Brookfield Engineering Labs., Inc. Page 11 Manual No. M/97-241-B1101590 119.0 660 122.8 730 126.8 800 131.2 870 134.7 940 137.6 1010 139.9 1080 141.05

Pagina 4 - THAN 40 PSI TO THE SWITCH!

Brookfield Engineering Labs., Inc. Page 12 Manual No. M/97-241-B1101 Appendix B - ReferencesThe KU-1+ Viscometer is compatible with:ASTM D 562 Standar

Pagina 5 - Container Dimensions

Brookfield Engineering Labs., Inc. Page 13 Manual No. M/97-241-B1101 Appendix C - Warranty Repair and ServiceWarrantyBrookfield Viscometers are guaran

Pagina 6 - II. OPERATION

Brookfield Engineering Labs., Inc. Page 2 Manual No. M/97-241-B1101TABLE OF CONTENTS I. INTRODUCTION ...

Pagina 7 - ----g ---.-KU

Brookfield Engineering Labs., Inc. Page 3 Manual No. M/97-241-B1101 I. INTRODUCTIONThe Brookfield KU-1+ Viscometer measures fluid viscosity in Krebs u

Pagina 8

Brookfield Engineering Labs., Inc. Page 4 Manual No. M/97-241-B1101I.2 OptionsI.2.1 Air PurgeThe air purge option (Brookfield Part No.KU-1A) allows th

Pagina 9

Brookfield Engineering Labs., Inc. Page 5 Manual No. M/97-241-B1101I.4 Can SpecificationsContainer DimensionsCan Height Bottom Flange DiameterU.S. Pin

Pagina 10

Brookfield Engineering Labs., Inc. Page 6 Manual No. M/97-241-B1101 II. OPERATIONII.1 Set-Up1) Be sure that the power switch is off. Attach the power

Pagina 11

Brookfield Engineering Labs., Inc. Page 7 Manual No. M/97-241-B1101has been put into the container, the surface of the fluid will be at the immersion

Pagina 12 - Appendix B - References

Brookfield Engineering Labs., Inc. Page 8 Manual No. M/97-241-B1101 Appendix A - KU-1+ Calibration InformationThe accuracy of the KU-1+ is verified us

Pagina 13

Brookfield Engineering Labs., Inc. Page 9 Manual No. M/97-241-B11016) After you have recorded results in KU, then move the Selector knob to the "

Comentarios a estos manuales

Sin comentarios